Category: Fixed Gas Detectors
Showing 1–16 of 46 results
Grid view List view Air Alert – Standalone Transmitter Toxic Gas Detector Features Electrochemical, Infrared, or PID sensor element
Wire powered (3-wire), 12-35 VDC operating voltage, optional AC power supply
Operating temperature range of -40°C to +70°C
3 Push-button interface (ADD, MENU, SUB) with 3 corresponding magnetic, non-intrusive switches
2 Dry contact relays (optional) Graphical LCD with LED backlight
Output options: 4-20mA (3-wire) analog, RS-485 Modbus, optional 900 MHz or 2.4 GHz radio
Optional 3 color LED perimeter and audible alarm
1-Year warranty
AirLink 6900 – Wireless Gas Detector Explosion Proof Transmitter Features Electrochemical, PID, or IR sensors
Wireless communication 900 MHz radio and 52 networks 2.4 GHz radio and 78 networks
Dual battery powered
Battery life 2-year max – electrochemical sensors 1-year max low-power infrared sensors
Graphical LCD with LED backlight, readable in sunlight
3 Push-button interface (ADD, MENU, SUB) with corresponding magnetic, non-intrusive switches
Explosion/flame-proof certification for select gases
1-Year warranty
Optional remote-mount sensor kit with enclosure
AirLink VOC Pro – Wireless Monitoring 3-Wire Explosion Proof Transmitter Features PID sensor options: 10.0 eV lamp / 11.7 eV / 10.6 eV ppb / 10.6 eV ppm
Wired power (3-Wire), 12 to 35 VDC operating voltage
Output options: Wireless 900 MHz, or 2.4 GHz 4-20mA (3-wire) analog RS-485 modbus (4 wire)
Operating temperature range -40° C to +54°C
Graphical LCD with LED backlight
3 Push-button interface (ADD, MENU, SUB) with corresponding magnetic, non-intrusive switches
2 Individually configurable alarms
2 Front panel LED indicators (amber and red)
2 Optional fully programmable alarm relays (dry contacts)
1-Year warranty (see specifications)
Beacon 110 Beacon 110 Single Channel Wall Mount Controller Features Low cost versatile solution Compact, weatherproof, NEMA 4X enclosure 115/220 VAC or 24 VDC operation Long life sensors (2+ years typical) Accepts RKI LEL/O2/H2S/CO direct connect sensors Accepts any 4-20 mA transmitter Audible alarm with reset button Two programmable alarm levels Built-in trouble alarm with relay Relay rating 10 amps, form C Provides 4-20 mA output T2A Gas Detector 2-Wire Explosion Proof Transmitter Features Electrochemical Sensor
Loop-Powered (2-Wired), 4-20 mA output
3 Character, 7 segment display screen with backlight
3 Push-button interface (ADD, MENU, SUB) with corresponding magnetic, non-intrusive switches
Operating temperature range -40° C to +60°C
Aluminum device enclosure
303 Stainless-steel sensor housing
1-Year warranty
T3A Gas Detector 3-Wire Explosion Proof Transmitter Features Electrochemical, Infrared or catalytic bead sensors
Wire powered (3-Wire), 12 to 35 VDC operating voltage
Operating temperature range -40°C to +60°C
LCD display with LED back-light
3 Push-button interface (ADD, MENU, SUB)
Non-intrusive buttons using magnetic wand
2 Individually configurable alarms
2 Front panel LED indicators (amber and red)
2 Optional fully programmable alarm relays (dry contacts)
Output options: 4-20mA (3-wire) analog, RS-485 Modbus, both standard Industry Applications
VOC Pro – PID Gas Detector 3-Wire Explosion Proof Transmitter Features PID sensor options: 10.0 eV lamp / 11.7 eV / 10.6 eV ppb / 10.6 eV ppm
Wired power (3-Wire), 12 to 35 VDC operating voltage
Operating temperature range -40° C to +54°C
Graphical LCD with LED backlight
3 Push-button interface (ADD, MENU, SUB) with corresponding magnetic, non-intrusive switches
2 Individually configurable alarms
2 Front panel LED indicators (amber and red)
2 Optional fully programmable alarm relays (dry contacts)
Output options: 4-20mA (3-wire) analog, RS-485 modbus (4 wire)
1-Year warranty (see specifications)
Airlink T3A Wireless Monitor Explosion Proof Transmitter Features Electrochemical, Infrared, catalytic bead sensor element Wire powered (3-Wire), 12 to 35 VDC operating voltage
Output options: Wireless 900 MHz or 2.4 GHz 4-20mA (3-wire) analog RS-485 modbus
Digital Modbus output
Operating temperature range -40° C to +60°C
Graphical LCD with LED backlight
3 Push-button interface (ADD, MENU, SUB) with 3 corresponding magnetic, non-intrusive switches
2 Individually configurable alarms
2 Front panel LED indicators (amber and red)
2 Optional fully programmable alarm relays (dry contacts)
Beacon 200 Beacon 200 Two Channel Wall Mount Controller Features Simultaneous readout on 2 channels Two alarm levels per channel Discrete and common relays NEMA 4X enclosure 4-20 mA outputs Proven, long-life sensors for a wide variety of gases Accepts any 4-20 mA transmitter input (24 VDC) Easy to install, operate and expand S2 Series – Gas Sensor/Transmitter Diffusion Gas Sensor – Fixed Systems Features Available gases include – LEL, H2S, CO, PPM H2, and CO2 – Toxic gases include NH3, AsH3, Cl2, ClO2, HCN, & SO2 Infrared sensor for combustibles and CO2 Hydrogen-Specific now available Patented water repellent sensor coating 4-20 mA output Explosion proof construction Optional stainless steel junction box Beacon 410A Beacon 410A Four Channel Wall Mount Controller Features Simultaneously control up to 4 gas monitoring channels OLED display of all 4 channels LEL / O2 / CO2 / toxic direct connect sensors Accepts any 4-20 mA transmitter, 2 or 3 wire Up to 3 programmable alarm levels per channel Up to 3 configurable alarm relays per channel 4-20 mA analog & Modbus digital output standard 115 / 220 VAC or 24 VDC operation Audible alarm with silence feature RFI / EMI Resistant Alarm reset switch Built in trouble alarm with relay Weather and corrosion resistant NEMA 4X enclosure AirLink 6940NXP Wireless AC Powered Quad head Features Electrochemical, PID, or low power IR sensors Wireless communication 900 MHz radio and 52 networks 2.4 GHz radio and 78 networks AC powered with integrated backup battery pack Graphical LCD with LED backlight Adjustable background gas setting per setting 4 Push-button interface (MENU, ADD, SUB, and BACK) with 4 corresponding magnetic, non-intrusive switches Sensor warranty subject to factory verification 1-Year limited hardware warranty AirLink 6940XP Wireless Battery Powered Explosion Proof Transmitter Features Electrochemical, PID, or low power IR sensors Wireless communication 900 MHz radio and 52 networks 2.4 GHz radio and 78 networks Battery powered: 3.6 V/76 Ah battery pack (non-rechargeable) Battery life 6-months maximum 2-weeks plus for PID Graphical LCD with LED backlight 3 Push-button interface (ADD, MENU, SUB) with 4 corresponding magnetic, non-intrusive switches Sensor warranty subject to factory verification 1-Year limited hardware warranty Beacon 800 Beacon 800 Eight Channel Wall Mount Controller Features Capable of up to 8 separate channels Digital display of all 8 channels simultaneously Compact, weatherproof, NEMA 4X enclosure 85 to 264 VAC or 24 VDC operation Long life sensors (2+ years typical) Accepts any 4-20 mA transmitter Audible alarm with reset button Two programmable alarm levels per channel Common alarm and fail relays Relay rating 3 amps, form C Low cost versatile solution Direct Connect Sensors Fixed Gas Detection Features Available gases include LEL, H2S, CO, & CO2 Toxic sensors include NH3, AsH3, Cl2, ClO2, HCN, & SO2 Infrared sensors for combustibles and CO2 Patented water repellent sensor coating Explosion proof construction Optional stainless steel junction box M2A Series Stand Alone Explosion Proof Transmitter Features Operates with or without a controller Direct digital readout with OLED cold temperature display Available gases include ◦ LEL, O2, H2S, CO, CO2, and 100% Vol CH4 ◦ Toxic gases include NH3, AsH3, Cl2, ClO2, HCN, & SO2 Infrared sensor for combustibles and CO2 4-20 mA & digital Modbus outputs standard 2 fully programmable alarm relays & fail relay Non-intrusive calibration via magnetic wand Explosion proof construction Patented water repellent sensor cover User friendly setup, push buttons & OLED menus Long-life sensors (2 + years typical)