4 Gas, Confined Space, Gas Monitor. Features Simultaneous Detection of LEL, O2, H2S & CO. World's Smallest and Lightest Portable Multi Gas Detector. MSHA

GX-2009 (discontinued product)

View 360 Image

The GX-2009 standard model has been discontinued
Please see GX-2009 MSHA version

Confined Space 4 Gas Monitor

Features

  • Simultaneous detection of 4 gases, LEL, O2, H2S & CO
  • Smallest / Lightest 4 gas monitor on the market
  • Dual audible alarm ports
  • 3 visual alarm LED’s
  • Vibration alarm
  • IP-67 water-resistant/dustproof design
  • Calibration and bump test lock out or reminder controls
  • 20 hours of operation (NiMH batteries)
  • Automatic backlighting at alarm
  • Impact resistant over-mold body, RFI shielded body
  • STEL and TWA readouts
  • Intrinsically safe, CSA, C/US classified, IECEx / ATEX approved, SOLAS XI-1/7 Compliant, MSHA approved version available
Contact Sales

Overview

The smallest and lightest 4-gas portable multi gas detector in the world. Weighing only 4.6 ounces, it fits in the palm of your hand (2.75” H x 2.95” L x .98” D). The GX-2009 simultaneously monitors and displays combustibles, oxygen, carbon monoxide, and hydrogen sulfide. The GX-2009 represents the latest evolution of gas detection technology. Advancements include dual audible alarm ports and alarm LED’s on 3 sides of the instrument, so that alarm conditions are obvious from multiple perspectives especially in high noise environments. Other features include a water resistant and dust-proof design with IP 67 rating, an impact resistant rubber over-mold body that is RFI resistant, and a large capacity data logging system included as standard. Other standard features are vibration alarm, auto-calibration, calibration and bump test lock out or reminder control, STEL / TWA readings, peak hold, auto backlighting at alarm on a large LCD display, and it even tells the time! All of these controls and features are operated through 2 simple glove friendly buttons.

The NiMH battery set will operate for 20 hours and will fully charge in 3 hours. A huge capacity data logging function is a standard feature on all GX-2009 instruments. The data logging software will store up to 100 calibration records and is Windows XP, 7, 8, and 10. The GX-2009 is also functional with the SDM-2009 single calibration station and the Data Cal 2000 instrument maintenance system. The GX-2009 is designed around RKI’s compact and proven sensors, utilizing catalytic combustion, electrochemical and galvanic sensor technologies. Each miniaturized sensor is manufactured with the same high quality control that has made RKI sensors and instruments the most reliable and long lasting monitoring devices in the industry

GX-2009 Mining Version

RKI is proud to offer the smallest and lightest 4-gas monitor with an MSHA approval. MSHA (Mine Safety and Health Administration) approval allows this version of the GX-2009 to be used in underground mines, tunnels and excavations under MSHA jurisdiction. The GX-2009 Mining Version simultaneously monitors and displays % volume combustibles, oxygen, carbon monoxide, and hydrogen sulfide. MSHA Datasheet for more information GX2009, GX 2009

Portable Multi Gas Detector Configurations

  •  4 gas, LEL / O2 / H2S / CO • 3 gas, LEL / O2 / H2S • 3 gas, LEL / O2 / CO
  • 2 gas, LEL / O2 • 2 gas, O2 / H2S • 2 gas, O2 / CO
  • Single gas LEL, O2, CO, H2S

 

Application

  • Personal monitoring
  • Confined spaces
  • Refineries/petrochemical
  • Utilities
  • Hazardous material
  • Water/wastewater
  • Fire services
  • Construction

Specifications

The GX-2009 is designed around RKI’s compact and proven sensors, utilizing catalytic combustion, electrochemical and galvanic sensor technologies. Each miniaturized sensor is manufactured with the same high quality control that has made RKI sensors and instruments the most reliable and long lasting monitoring devices in the industry.

Gas Detected
Combustible Gases (Methane as standard)
Oxygen (O2)
Hydrogen Sulfide (H2S)
Carbon Monoxide (CO)
Detection Principle
Catalytic combustion
Galvanic cell
Electrochemical cell
Detection Range (Increments) 0 ~ 100% LEL (1% LEL) 0 ~ 40.0% Vol.
(0.1% Vol.)
0 ~ 100.0 ppm (0.5 ppm) 0 ~ 500 ppm (1 ppm)
Accuracy Statement ± 5% of reading or ± 2% LEL (whichever is greater) ± 0.5% O2 ± 5% of reading or ± 2 ppm H2S (whichever is greater) ± 5% of reading or ± 5 ppm CO
(whichever is greater)
Sampling Method Diffusion sampling standard / hand aspirator or motorized pump optional
Display Digital LCD displays all four gases simultaneously, with auto backlight
Preset Alarms
(User Adjustable)
Overscale alarm
(Non-adjustable)
1st alarm 10% LEL
2nd alarm 50% LEL
Over alarm 100% LEL
Low alarm 19.5%
High alarm 23.5%
Over alarm 40.0%
1st alarm 5 ppm
2nd alarm 30 ppm
TWA alarm 1 ppm
STEL alarm 5 ppm
Over alarm 100 ppm
1st alarm 25 ppm
2nd alarm 50 ppm
TWA alarm 25 ppm
STEL alarm 200 ppm
Over alarm 500 ppm
Types of Alarms Gas Alarm: 2 Increasing alarms, STEL, TWA, overscale alarm. O2 decreasing/increasing.
Trouble alarm: Sensor disconnection, low battery, circuit error, calibration range error
Display of Alarm Gas Alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), flashing gas value, vibration

Trouble alarm: Flashing LEDs, intermittent buzzer (95 db @ 30 cm), display of error message

Operating Temp. & Humidity -4°F to 122°F (-20°C ~ +50°C), 0 to 95% RH, non-condensing (splash resistant)
Response Time Within 30 seconds (T90)
Continuous Operation 20 hours after a 3 hour full charge (14 hours after 90 min charge)
Power Source Direct charging NiMH batteries, set of 2
Safety Design / Approvals IECEx zone 0 Ex ia IIC T4; ATEX II 1G Ex ia IIC T4; (optional MSHA version also available)
c CSA us classified, as intrinsically safe. Class I, Division 1, Groups A, B, C, D
Dimension & Weight 2.7” H x 3” W x 1” D (Approx. 70 H x 75 W x 25 D mm), 4.6 ounces (approx. 130 g)
Case Material High impact over molded rubber. Dust and water resistant with IP-67 approval.
Controls Two buttons: POWER / MODE, AIR
Datalogging Standard with all instruments. Stores 8 alarm trend sessions where readings are recorded 30 minutes
before and after an alarm event. 3,600 data point capacity with a log time range of 10 to 300 hours
(based on programmable interval times); and stores up to 100 calibration records.
Required Accessories Battery charger
Standard Accessories Alligator clip 13-0116RK
NiMH batteries (set of 2) 49-1609RK
Charging station with 115/220 VAC power supply (also available without power supply, 49-2170RK) 49-2170RK-01
Product CD (includes datalogging software) 71-8002RK
Optional Accessories Belt Clip 13-0117RK
Padded carrying case for GX-2009 and accessories 20-0112RK-01
Charging station, 115/220 VAC powered for 2, 3, 4, or 5 instruments 49-2170RK-XX
Charging station with 12 VDC power supply and vehicle adapter plug 49-2171RK
12 VDC adapter with vehicle plug (does not include charger base) 49-2020RK
RP-2009 pump with 4” rubber nipple, 10’ hose and probe (up to 40’ hose available) 81-1177RK
RP-6 sample drawing pump with 10’ hose and probe (up to 40’ hose available) 81-1166RK
Hand aspirated sample draw with 10’ hose and probe (up to 40’ hose available) 81-1160RK
USB to IrDA downloading cable 47-5084RK-01
SDM-2009 single calibration station 81-SDM2009-01
Configurations
  • 4 gas, LEL / O2 / H2S / CO
  • 3 gas, LEL / O2 / H2S
  • 3 gas, LEL / O2 / CO
  • 2 gas, LEL / O2
  • 2 gas, O2 / H2S
  • 2 gas, O2 / CO
  • Single gas LEL, O2, CO, or H2S
Warranty Two years material and workmanship

Parts

# Part Number Description
1 21-1880RK Front case, GX-2009
2 07-6017RK-01 Gasket for GX-2009 case, one each
3 30-1054RK Vibration motor for the GX-2009
4 51-1119RK LCD module assembly with flat cable for GX-2009
5 57-2052RK PCB main assembly, GX-2009
5 65-7001RK Dummy sensor for GX-2001 or GX-2009
6 21-1881RK Case, rear, GX-2009
7 10-1098RK-01 Screw with split lock and flat washers for alligator or belt clip, GX-2009, 1 each
8 10-1104RK Screw for case or sensor retainer, M2 x 10 mm, GX-2001 or GX-2009, pack of 100
9 33-1113RK-01 Metal mesh filter for buzzer hole, GX-2009, 1 each
9 49-0115RK 115 / 220 VAC Adapter for charger (charger base not included), GX-2009
10 07-6018RK Gasket for buzzer hole, GX-2009
11 24-5000RK Flexible printed circuit (FPC), GX-2009
12 49-1050RK Battery, silver oxide, SR 616, 1.55 volts, GX-2009
13 49-1609RK NiMH battery set with hardware for GX-2009, set of 2 batteries
14 13-0119RK Alligator clip, GX-2009
17 21-1883RK Sensor case with PCB assembly, GX-2009
18 07-6008RK O-ring gasket for sensor case, GX-2009, pack of 10
18 07-6008RK-01 O-ring gasket for sensor case, GX-2009, 1 each
19 OS-BM2 Sensor, Oxygen (O2) for GX-2001/GX-2003/GX-2009/GasWatch 2/OX-01
20 NC-6264A Sensor, LEL, for GX-2001/GX-2003/GX-2009/GP-01
21 ES-1821 Sensor, Carbon Monoxide (CO) for GX-2001/GX-2003/GX-2009/GasWatch 2/CO-01
22 ES-1827i Sensor, Hydrogen Sulfide (H2S) for GX-2009
23 07-6019RK Sensor chamber gasket,for sensor retainer,GX-2009
24 21-1882RK Sensor retainer, GX-2009 (inner piece)
25 33-7114RK Filter disk, H2S scrubber, 5 pack, for combustible diffusion port, set of 5
26 33-7102RK Filter, charcoal, for CO sensor, pack of 5
26 33-7102RK-01 Filter, charcoal, for CO sensor, 1 each
27 07-6021RK Gasket, sensor retainer
28 33-0172RK Sensor Cover, water proof, sheet for 4 sensors, GX-2009, 1 each
29 21-1884RK Sensor cover, GX-2009 (outside piece)
30 10-1104RK-01 Screw for case or sensor retainer, M2 x 10 mm, GX-2001 or GX-2009, 1 each
31 13-0112RK Wrist strap, GX-2001/GX-2003
32 21-1885RK Sensor cap assembly, GX-2009

Download

Training Video

This video is also available on YouTube and CD (by request)

Contact Image

Contact Us

Best Selling

You Might Also Like

© 2024 RKI Instruments. All Rights Reserved | Gas Detectors | Portable Gas Monitors | Gas Sensors