by Fmeaddons

Portable HC/02 Sample Draw Gas Detector

Features

  • Real-time detection combustible gas, 100%vol./ 100%LEL & O2
  • Large simultaneous display with auto back lighting
  • Strong sample drawing capability
  • Loud alarm buzzer with 95dB
  • 3 bright LED alarm indicators
  • ATEX Exia II CT4/MED approved
  • Water and dust resistant IP67
  • Lithium-ion rechargeable battery
  • Compact and lightweight
  • Internal sample draw pump
  • Ergonomic design with wrist strap for hands free operation
  • Datalogging standard
Category:

Contact RKI Sales

Description

The RX-8000 is an ideal multigas monitor for marine applications.

Applications

  • Oil Tanker
  • Gas Carrier
  • Product Tanker
  • Refineries, Petrochemical, Chemical Plants
  • Confined Space Entry
  • Gas Plant, Gas Supplier Services
  • Power Plant
  • Chemical Tanker
  • Wastewater Treatment / Water
  • Utilities

Overview

The RX-8000 sets the new industry standard for rugged, reliable portable gas detection. It’s tough, water proof design utilized features based on years of gas detection design experience, to assure that the instrument will operate properly to protect workers and property in all kinds of harsh gas detection applications.

Specifications

Target Gas
Combustibles (i-CH410 or CH4 calibration)
Oxygen
Detection Principle
Non-Dispersive Infrared (IR)
Galvanic Cell
Detection Range (Increments)
0-100vol% (0.5vol%)
0-100%LEL (0.5%LEL)
0-40.0% (0.1%)
Accuracy
±5vol%
±5vol%

Range 0-25%: ±0.7
Range 26-40%: ±3.0

Response Time
T90 within 30 seconds
T90 within 20 seconds
Sampling Method
Sample Draw: Minimum 0.75L/min
Gas Alarm
N/A

1st: 10%LEL
2nd: 50%LEL

1st: 19.5%
2nd: 23.5%
Display of Alarm LED: LED’s flash
Buzzer: 95dB
Visual Indication: Indication value flashes. Alarm message displays and flashes
Display Digital display and bar graph
Power Source Lithium-ion battery (3 hours for a full charge): Standard
AA Alkaline battery (qty 3): Option
Continuous Operation Lithium-ion battery: 15 hours
AA Alkaline battery: 10 hours
Operating Temp & Humidity -20 ~ +50C (-4 ~ +122F) below 95%Rh (non-condensing)
Dimensions & Weight 6.1″W x 3.1″H x 5″ D, 2.4lbs
Ingress Proof Rating IP67
Explosion Proof Ex ia IIC T4 Ga
Approvals IECEx, ATEX, MED, Complying to IEC60079-29-1, EN50104
Additional Features Indication to show energizing (pilot indicator and pump driving indicator), activating confirmation IrDA communication, data logger, password protection

Download

RX-8000 Software & Documents

Software Product Datasheet RX-8000 Manuals

download
RX-8000 datalogging program

30.5MB

download
RX-8000 Fact Configs HC

29MB

download
RX-8000 Fact Configs CH4

29MB

RX-8000 Datasheet
RX-8000 Product Datasheet

RX-8000 Manual

RX-8000 Operator’s Manual

RX-8000 Supplement
RX-8000 Alarm Function Supplement

RX-8000 Datalogging Manual

RX-8000 Datalogging Manual