RKI’s new SDM-2009 calibration station for the GX-2009 is now available with advanced features for charging, calibration, & bump testing. Once you power up the GX-2009 inside the SDM-2009 calibration module, the GX-2009’s display will indicate whether it’s transmitting data, bump testing, calibrating, as well as the results of the bump test or calibration.
Multi Module System
The SDM-2009 can also be connected to a PC for automated calibration, bump testing, and archiving of logged data including calibration and bump test records, interval and alarm trends.
Network up to 10 SDM-2009 stations to charge, calibrate, and bump test 10 instruments simultaneously.
User Guide Poster
Each SDM-2009 ships with a pictorial wall chart user guide. This guide gives the already easy to use cal station a simple pictorial easy step by step guide to calibrating or bump testing a GX-2009. It’s ideal to hang in an instrument shop or wherever the GX-2009 is located.
Features
Stand Alone Station
Multi Module System
Input Power |
12 VDC NOTE: AC Adapter with 100 - 240 VAC, 50/60 Hz, 0.6A input and 12 VDC, 1.2A output provided as standard. |
Environmental Conditions |
• For Indoor Use Only • -10° C to 40° C, below 80% Relative Humidity, Non-Condensing |
Applicable Instruments |
GX-2009 |
Maximum Number of Records Saved |
200 (stand-alone). Unlimited with software |
Number of Calibration Gas Cylinders |
1 Calibration gas, 1 fresh air and 1 exhaust |
Standard Accessories |
|
Docking Station |
|
| 81-SDM2009-01 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing & installation CD |
| 81-SDM2009-02 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, & demand flow regulator |
| 81-SDM2009-03 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 58AL cyl H2S (25 ppm)/CO/CH4/O2 |
| 81-SDM2009-06 | Single point calibration station for GX-2009, model SDM-2009 with AC Adaptor, flash drive, USB cable, tubing, installation CD, demand flow regulator & 34AL cyl H2S (25 ppm)/CO/CH4/O2 |
Calibration Equipment and Accessories |
|
| 81-0090RK-01 | Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 34L |
| 81-0090RK-03 | Cylinder, CO 50 ppm / Methane 50% LEL / O2 12 % in N2, 103L |
| 81-0154RK-02 | Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 58AL |
| 81-0154RK-04 | Cylinder, H2S 25 ppm / CO 50 ppm / CH4 50% LEL / O2 12% in N2, 34AL |
| 81-0158RK-02 | Cylinder, H2S 25 ppm / CO 50 ppm / isobutane 50% LEL / O2 12% in N2, 34AL |
| 81-0158RK-04 | Cylinder, H2S 25 ppm / CO 50 ppm / isobutane 50% LEL / O2 12% in N2, 58AL |
| 81-1054RK | Regulator, demand flow for 34AL/58AL/103L |
| 81-1055RK | Regulator, demand flow for 17L/34L steel cylinders |
| 82-6050RK | USB Hub, 4 port 2.0 for SDM-2012 |
| 82-6051RK | USB Hub, 7 port 2.0 for SDM-2012 |
| 71-8007RK | SDM-GX Product CD |
Specifications subject to change without notice.
Adobe Acrobat Reader® required for viewing
Introduction | Description | Operation
Calibration | Maintenance | Setup Mode | PID Sensor
EAGLE 2 PID Response Factors for VOCs
Photoionization detectors are calibrated using isobutylene, but PID is a broadband VOC detection technique, with a sensitivity that differs for each VOC. If you know what VOC you are detecting, then the table below will allow you to calculate the concentration for your specific VOC. Remember, these are approximate values, so for best accuracy you should calibrate with the relevant VOC.
Multiply the indicated concentration by the appropriate Relative Response value to provide an estimate of actual VOC concentration.
Gas / VOC |
CAS No. |
Formula |
Relative |