| Part # |
H2 Specific LEL
65-2450RK |
H2 Specific ppm
65-2440RK |
| Detection Range |
0 - 100% LEL |
0 - 2000 ppm |
Min Operating
Voltage
|
11 VDC |
Max Operating
Voltage |
30 VDC |
Max Current
Draw
|
200 mA (power wires)
25 mA (signal wires) 3 wires |
100 mA (power wires)
25 mA (signal wires) 3 wires |
| Signal Output |
4 mA at 0% LEL
20 mA at 100% LEL
Linear Output |
4 mA @ 0 ppm
20 mA @ 2000 ppm
Linear Output |
Response
Time
|
20 Seconds to 90% concentration |
20 Seconds to 90% concentration |
| Operating Environment |
| Location |
Indoor or outdoor.
Explosion proof for
Class , Div. 1,
Groups B, C, and D.
|
Indoor or outdoor.
Explosion proof
housing and
intrinsically safe sensor. |
| Temperature |
-40 to 180° F |
15 to 110° F |
| Humidity |
5-95% RH non-condensing |
| Housing |
Enclosure: Aluminum Explosion Proof
Sensor: Stainless steel and aluminum |
| Sensor |
| Type |
Catalytic combustion
with molecular sieve |
Metal oxide semiconductor
with molecular sieve |
| Life Expectancy |
Over 3 years typical |
Over 5 years typical |
| Controls |
| Sensor Current |
Factory set and sealed |
| Zero |
Sets transmitter output to 4 mA
with 0% LEL output from
combustible sensor |
Sets transmitter output to 4 mA
with 0 ppm output from sensor |
| Span |
Sets transmitter output to 20 mA
with 100% LEL output from
combustible sensor |
Sets transmitter output to 20 mA
with 2000 ppm Hydrogen output
from sensor |
| Tools Needed |
Calibration kit, Screwdriver, and voltmeter used to make adjustments. |
| Calibration Frequency |
6 Months |
12 Months |
|
Warranty
|
One year
|
* Specifications subject to change without notice