This model is a highly sensitive C5F8 / C4F6 / or C3F6 gas monitor which uses a special techniquie for detecting C5F8, C4F6 or C3F6. into more readily detectable compounds.
Then, the resulting compounds cause a chemical reaction on a colorimetric tape, and the intensity of the chemical reaction is analyzed and correlated to a specific ppm level of C5F8, C4F6 or C3F6 present in the sample. The detection tape is in a handy cassette which is easily removed for periodic replacement.
Features
Applications
Detectable Gases and Detection Ranges
Gas |
Detection Range |
Resolution |
Warning |
Alarm |
Detection Cycle |
Tape No. |
C5F8 |
0~5.0ppm |
0.1ppm |
2.0ppm |
4.0ppm |
20 sec |
FV-017 |
C4F6 |
0~150ppb |
0.1ppm |
2.0ppm |
4.0ppm |
20 sec |
FV-017 |
C3F6 |
0~3.0ppm |
0.1ppm |
0.9ppm |
2.0ppm |
20 sec |
FV-117 |
Specifications
Model |
FP-260AGZS |
| Structure | Desktop type, transportable |
Detection principle |
Special pyrolyzer + Photoelectric photometry method using tape cassette |
Detection tape |
Plug in cassette |
Detection cycle |
20 seconds |
Measuring gas and range |
see table above |
Accuracy |
Within +/- 20% +1 of indication |
Tape operation time |
1 month (for gas free condition) Tape remainder display and caution display for end of tape. |
Sampling method |
Automatic sampling (1 l/min) with internal pump |
Gas Concentration readout |
Direct reading with digital display |
Alarm Preset Levels |
Warning: 2.0ppm, Alarm 4.0ppm |
Alarm Accuracy |
Better than +/- 30% +1 digit of alarm setting value at constant condition |
Alarm Display |
Warning: Blinking yellow light Alarm: Blinking red light (steady light after restart) |
Relay Contact |
Latched mode (standard) or non-latched mode (optional). Form C (dry contacts) for both warning and alarm. Rated 0.5A at 125VAC. |
Alarm functions |
Latching (standard) or self reset. Lamp (Caution: Yellow, Warning: Red) and buzzer |
Self diagnosis |
Sensor failure, low flow, tape failure, tape cut, tape replacement, tape end, tape failure, tape set failure, system trouble, motor trouble. Output: Form C, dry contacts non-latched mode, rated 0.5A at 125VAC |
External output signal |
4-20mA DC (0-1V DC optional) BL-NET (optional) |
Operating temperature & humidity |
10~35°C, 30~60% RH (non condensing) |
Gas Inlet |
Outer diameter: 6mm, with fitting for PTFE tubing |
Power supply & power |
110VAC, 110 VAC, 115VAC, 220VAC (80VA) |
Dimensions & weight |
Approx. 275(W) x 220(H) x 370(D)mm Approx. 12 kg |
Standard Accessories |