Gas Detection For Life

Leading gas detector manufacturer

 

RKI banner
Fixed Systems

M2 Series

Stand Alone Transmitter

M2 SeriesExplosion proof housing, patented water repellent sensor coating.

Operates independent of controller. Available for LEL HC, H2S, CO, O2, & ppm HC

Long life sensors (2+ years typical)

M2-Series

S2-Series

Diffusion Sensor/Transmitter

S-SeriesBasic 4-20 mA transmitters for the detection of common gas hazards.
LEL (catalytic), LEL (IR) CH4, LEL (IR) HC, O2, H2S, CO, or CO2 (IR) versions available.

S-Series

Beacon 110

Single Channel Wall Mount Controller

Beacon 110Sensors can be mounted directly at the Beacon 110 housing, or can be wired remote from the controller.

Beacon 110

Beacon 410

Four Channel Wall Mount Controller

Beacon 410Simultaneously displays the gas type, readings, and status of 4 channels. Accepts direct connect sensors for LEL / O2 / H2S / CO / CO2.

Audible alarm with silence feature

Beacon 410

PS-2

Single Point Stand Alone Monitor

PS-2LEL or PPM detection ranges available.

A perfect low cost solution for hydrogen detection in battery rooms.

PS-2 Model

Drill Rig Monitors

H2S Monitoring for Drill Sites

Drill Rig MonitorThese monitors are specifically designed for detection of H2S around temporary drilling rigs. All units include our long-life plug in electrochemical H2S sensor, range 0-100 ppm.

RM Series

Controllers

See more Fixed System Controllers

Beacon 410
Simultaneously displays the gas type, readings, and status of 4 channels. Accepts direct connect sensors for LEL / O2 / H2S / CO / CO2. Beacon 410

Sensors

See more Fixed System Detectors

GD-70D
The GD-70D can be used as a stand-alone device, offering a number of communication protocols GD-70D

Paper Tape

See all the Paper Tape Instruments

FP-330
The FP-300 is a highly sensitive paper tape gas detector for detecting formaldehyde.
FP-330

Air Aspirator Gas Monitor

Harsh Environment Sampling System

DigesterSingle or dual sensor system is designed to monitor gas atmospheres from extreme conditions with either temperature, moisture, or pressure challenges. A powerful air aspirator can pull a sample from up to 100 feet away. The filtered and conditioned sample gas is then passed across one or two different detectors. Each detector shares a common calibration and compressed air inlet for aspirated flow. This system is fault tolerant removing the need for expensive downtime and maintenance. The sample is diluted with air after the gas sensor and then returned to a common exhaust reducing the danger of potential hazardous gases entering a safe work space.

Single / Dual Sensor Air Aspirator

Digester Gas Monitor

Harsh Environment Sampling System

Digester Gas MonitorGas from waste digesters contains high levels of methane, CO2, and H2S, with little to no oxygen present. The RKI gas monitor checks for all these gases on a cyclic basis. A powerful air aspirator pulls a sample from up to 100 feet away. Since digester gas contains high humidity and high H2S, both of which can cause damage to sampling systems, the RKI Digester Gas Monitor is designed to handle these with no damage to the sampling system or sensors. The sample is filtered through a series of dirt, dust, and moisture stopping filters, and these filters are automatically blown back and cleaned out with fresh air at the end of each cycle.

Digester Gas Monitor