Gas Detection For Life

Leading gas detector manufacturer

 

RKI banner
EAGLE 2

6 Gas Sample Drawing Monitor

EAGLE 2 gas monitorRKI is proud to offer the next generation of our popular EAGLE portable gas detector. Equipped with features that are not available on competitive units, the EAGLE 2 is a powerful instrument that does more than just offer the standard confined space protection for LEL, O2, H2S and CO.

The EAGLE 2 available features include a PID sensor for detecting high or low ppm levels (0-50 & 0-2,000) of VOC gases; % volume capability for CH4 and H2 using a TC (thermal conductivity) sensor; ppm or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2 (ppm or % volume), methane or hydrocarbons in LEL and % volume ranges;
Optional LEL / ppm H2 specific sensor, methane elimination feature for environmental applications; and a variety of super toxic gases.

Made in U.S.A.

  • Features
  • Specifications
  • Gases
  • Download
  • Video
  • PID Chart

Features

  • Test Monitor up to 6 different autoranging gases
  • PPM / LEL hydrocarbon detection
  • PID (Photo Ionization Detector) low and high range for VOC detection
  • Infrared Sensors available for CO2, % LEL CH4, % Vol. CH4, % LEL HC, % Vol. HC
  • TC (Thermal Conductivity) sensor available for % Vol. H2 or % Vol. CH4
  • Plug and play, smart toxic sensors
  • Hundreds of configurations
  • Displays in 5 languages
  • Powerful long-life pump up to 125’ range
  • Low flow pump shut off and alarm
  • Methane elimination for environmental use
  • Alkaline 18 hours or Ni-MH 20 hours capability
  • Password protection
  • Datalogging standard
  • IrDA communications port
  • Autocalibration/ single gas calibration
  • Internal hydrophobic dust filter
  • External probe with hydrophobic filter

 

EAGLE 2 gas meters

  • Ergonomic RFI / EMI / chemical / weather resistant enclosure
  • Intrinsically safe design, CSA approval

 

Eagle 2 calloutsUnique EAGLE 2 features include PPM or LEL hydrocarbon detection at the push of a button; infrared sensors for CO2, methane or hydrocarbons in LEL and % volume ranges; PID sensor for detecting high and low ppm levels (0-50 & 0-2,000) of VOC gases; methane elimination feature for environmental applications; and a list of super toxic gases and measurable ranges. The EAGLE 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 125 feet. This allows for quick response and recovery from distant sampling locations. The EAGLE 2 will continuously operate for over 18 hours on alkaline batteries or 20 hours on Ni-MH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, just to name a few. Datalogging is a standard feature for all sensors on all versions.

Enclosure

Weatherproof, chemical resistant, RFI / EMI coated high impact polycarbonate-PBT blend. Can operate in 2.0” of water without leakage. Ergonomically balanced with rugged top mounted handle. Water & dust resistant equivalent to IP64.

Dimensions

9.5” L x 5.25” W x 5.875” H

Weight

3.8 Lbs (standard 4 gas with batteries)

Detection Principle

Catalytic combustion, electrochemical cell, galvanic cell, infrared, photo ionization detector, and thermal conductivity.

Sensor Life

2 Years under normal conditions.

Sampling Method

Powerful, long-life pump (over 6,000 hours) can draw samples over 125 feet. Flow rate approximately 2.0 SCFH

Display

3 display modes: display all gases, large font-autoscroll, or large font-manual scroll. Polyurethane protected overlay. Backlight, illuminates for alarms and by demand with adjustable time.

Language

Readout can display in 5 languages (English, French, German, Italian, or Spanish.

Alarms

2 Alarms per channel plus TWA and STEL alarms for toxics. The two alarms are fully adjustable for levels, latching or self reset, and silenceable.

Alarm Method

Buzzer 95 dB at 30 cm, four high intensity LED’s.

Controls

4 External glove friendly push buttons for operation, demand zero, and autocalibration. Buttons also access LEL/ppm, alarm silence, peak hold, TWA/STEL values, battery status, conversion factors, and many other features.

Continuous Operation

At 70°F, 16 hours using alkaline batteries, or 18 hours using Ni-MH.

Power Source

4 Alkaline or Ni-MH, size C batteries (Charger has alkaline recognition to prevent battery damage if charging is attempted with alkalines).

Operating Temp. & Humidity

-20°C to 50°C (-4°F to 122°F), 0 to 95% RH, non-condensing.

Response Time

30 Seconds to 90% (for most gases) using standard 5 ft hose.

Safety Rating

Intrinsically Safe, Class I
Groups A, B, C, D.

Approvals: CSA / CE

Standard Accessories

Shoulder strap, alkaline batteries, hydrophobic probe, and 5 foot hose, internal hydrophobic filter

Optional Accessories

  • Dilution fitting (50/50)
  • Ni-MH batteries
  • Battery charger, 115 VAC, 220 VAC, or 12 VDC (charge time 4 hours) with continuous operation function
  • Extension hoses

Warranty

Two year material and workmanship, one year for PID sensor

 
Specifications subject to change without notice. 

Gases & Detectable Ranges

The EAGLE 2 can be configured with up to 6 gas sensors from the list below.

 

Standard Confined Space Gases

Gas Measuring Range Accuracy
(whichever is greater)

Hydrocarbons (CH4, std)

0 - 100% LEL

± 5% of reading or
± 2% LEL (*)

0 - 50,000 ppm

± 25 ppm or
± 5% of reading (*)

Oxygen (O2)

0 - 40% Vol.

0.5% O2

Carbon Monoxide (CO)

0 - 500 ppm

± 5% of reading or
± 5 ppm CO (*)

Hydrogen Sulfide (H2S)

0 - 100 ppm

± 5% of reading or
± 2 ppm H2S (*)

Toxics

Ammonia (NH3)

0 - 75 ppm

± 10% of reading or
± 5% of full scale (*)

Arsine (AsH3)

0 - 1.5 ppm

Chlorine (Cl2)

0 - 3 ppm

Hydrogen Cyanide (HCN)

0 - 15 ppm

Phosphine (PH3)

0 - 1 ppm

Sulfur Dioxide (SO2)

0 - 6 ppm

IR Sensors

Carbon Dioxide (CO2)

0 - 10,000 ppm

0 - 5% Vol.

0 - 60% Vol.

± 5% of reading or
± 2% of full scale (*)

Methane (CH4)

0 - 100% LEL

0 - 100% Vol.

Hydrocarbons

0 - 100% LEL
0 - 30% Vol.

PID Sensors

VOC

0 - 2,000 ppm
0 - 50 ppm

TC Sensors

Methane (CH4)

0 - 100% Vol.

± 5% of reading or
± 2% of full scale (*)

Hydrogen (H2)

0 - 10% Vol.
0 - 100% Vol.

 

Special Features
  • Low flow alarm shuts pump off to avoid damage to instrument.
  • Hydrophobic filter disc in probe.
  • Internal hydrophobic filter.
  • Single gas calibration capability.
  • Methane elimination feature for environmental applications.
  • Security Password protected.
  • Meets EPA Method 21 protocol for fugitive emissions testing (most applications).
  • Plug and play toxic sensors.
  • Datalogging available for all configurations.
  • Transformer gas testing version available.
Specifications subject to change without notice. 

Eagle 2 Video


This video will open in a new window. Also available on Youtube and CD (by request)

EAGLE 2 PID Response Factors for VOCs

Photoionization detectors are calibrated using isobutylene, but PID is a broadband VOC detection technique, with a sensitivity that differs for each VOC. If you know what VOC you are detecting, then the table below will allow you to calculate the concentration for your specific VOC. Remember, these are approximate values, so for best accuracy you should calibrate with the relevant VOC.

Multiply the indicated concentration by the appropriate Relative Response value to provide an estimate of actual VOC concentration.

spacer spacer spacer spacer

Gas / VOC

CAS No.

Formula

Relative
Response

 

The EAGLE 2 has a strong internal pump with a low flow auto pump shut off and alarm, which can draw samples from up to 125 feet. This allows for quick response and recovery from distant sampling locations. The EAGLE 2 will continuously operate for over 16 hours on alkaline batteries or 18 hours on NiMH. A variety of accessories are also available to help satisfy almost any application such as long sample hoses, special float probes for tank testing, and dilution fittings, just to name a few. Datalogging is a standard feature for all sensors on all versions.

With its ergonomic design and large glove friendly buttons, the EAGLE 2 offers easy access to controls such as auto calibration, alarm silence, demand zero, peak hold, methane elimination, and a wide variety of other features. Each channel has two alarm levels plus TWA and STEL alarms for toxic channels. The two alarm levels are user adjustable and can be latching or self resetting. Rugged, reliable, easy to operate and maintain, the EAGLE 2 is the solution for just about any portable gas monitoring situation. Also, the display can be set to any of 5 languages: English, French, German, Italian, or Spanish.

SDM-E2

Stand Alone Calibration Station

Eagle 2 Calibration StationA single module calibration station for the Eagle 2 portable gas monitor that can calibrate, bump test, charge, and archive data.

SDM-E2

Marine EAGLE 2

Tanker Tester Gas Monitor

Eagle 2 PID gas monitorVersatile portable gas detector specifically for maritime tanker

Test Monitor up to 6 different gases

PPM / LEL hydrocarbon detection

Tanker Tester for Marine